- LCD display.
- Data Storage500 sets.
- Support for USB and RS-232.
- IP54 waterproof.
Benchtop pH/Ion Meter, BEP-M400B
Description
Description
The BEP-M400B Benchtop pH/Ion Meter is suitable for health and disease control, environmental protection, biological agriculture and forestry, water quality analysis, scientific research and higher institutes and other fields.The ion-selective electrode method has the advantages of simple operation and low detection limit.
Features:
General Features
- High resolution LCD display, 5.7 inches.
- Multi-reading feature allows auto-read, timed-read and continuous-read.
- Automatic/Manual temperature compensation ensures accurate results.
- Auto-hold feature senses and locks the measurement endpoint.
- Data Storage500 sets (GLP-compliant).
- Support for USB and RS-232 communication.
- Reset feature automatically resumes all settings back to factory default options.
- IP54 waterproof.
pH:
- 1-5 points calibration with Standard Recognition.
- Selectable pH buffer groups, including NIST, DIN, GB.
- Automatic electrode diagnosis with pH slope and offset display.
Ion:
- 1-5 points calibration.
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, PX, etc.
- Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
- Over 10 methods are built-in, including F–, Cl–, Br–, I–, NO3–, BF4–, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+and etc., user-defined method is supported.
Model | BEP-M400B | |
Parameters | pH/ISE/Temp.(mV/pX) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 5 | |
Standard Customization | Yes | |
Standard Recognition | NIST, GB, DIN, USA and MERK buffers | |
Slope Limit | Yes | |
mV | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% of
reading whichever is greater |
|
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 5 | |
ISE | Range | 1E-9 to 9.999E9 |
Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 5 | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 500 results each |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
Temp. Probe | 4-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer | |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC9V output |
Dimensions | 242×195× 68 mm | |
Weight | 900g |
Matched electrode (Required option) | ||||
Model | Type | Measuring range | Electrode plug | Notes |
701 Na+ | Composite electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | |
PF-202-C | Composite electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | |
PF-202 | Composite electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | |
PNH3 -1-01 | Composite electrode | 5*10-6-0.1mol/L | BNC (Type Q9) | |
PF-2-01 | Single Electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | Used with reference electrode 232-01-X |
PF-3-01 | Single Electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | Used with reference electrode 232-01-X |
PCl-1-01 | Single Electrode | 5*10-5-0.1mol/L | BNC (Type Q9) | Used with reference electrode C(K2SO4)-1-X |
PBr-1-01 | Single Electrode | 5*10-6-0.1mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
PI-1-01 | Single Electrode | 5*10-7-0.1mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
PK-1-01 | Single Electrode | 1*10-5-0.1mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
PCa-1-01 | Single Electrode | 1*10-5-0.1mol/L | BNC (Type Q9) | Used with reference electrode 232-01-X |
PCu-1-01 | Single Electrode | 5*10-7-0.1mol/L | BNC (Type Q9) | Used with reference electrode C(K2SO4)-1-X |
PPb-1-01 | Single Electrode | 5*10-7-0.1mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
PNO3 -1-01 | Single Electrode | 1*10-5-0.1mol/L | BNC (Type Q9) | Used with reference electrode 232-01-X |
PClO4-1-01 | Single Electrode | 5*10-6-0.1mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
PAg/S-1-01 | Single Electrode | 3×10-7mol/L-0.1mol/L | BNC (Type Q9) | Used with reference electrode C(K2SO4)-1-X |
PBF4-1-01 | Single Electrode | 3×10-6mol/L-0.1mol/L | BNC (Type Q9) | Used with reference electrode 232-01-X |
PCN-1-01 | Single Electrode | 1*10-6-1*10-2mol/L | BNC (Type Q9) | Used with reference electrode 217-01-X |
972101 F- | Composite electrode | 1×10-6mol/L-saturated | BNC (Type Q9) | |
972102 Cl- | Composite electrode | 5*10-5-1mol/L | BNC (Type Q9) | |
972103 Br- | Composite electrode | 2*10-6-1mol/L | BNC (Type Q9) | |
972104 I- | Composite electrode | 1*10-7-1mol/L | BNC (Type Q9) | |
972105 Cu+ | Composite electrode | 1*10-7-0.1mol/L | BNC (Type Q9) | |
972106 Pb | Composite electrode | 1*10-6-0.1mol/L | BNC (Type Q9) | |
972207 Na+ | Composite electrode | 1×10-7mol/L-saturated | S7 | |
972121 K+ | Composite electrode | 1×10-6-1mol/L | BNC (Type Q9) | |
972122 (NH4+) | Composite electrode | 1×10-6-1mol/L | BNC (Type Q9) | |
972123 NO₃⁻ | Composite electrode | 1×10-5-1mol/L | BNC (Type Q9) | |
972124 Ca2+ | Composite electrode | 5*10-7-1mol/L | BNC (Type Q9) | |
972125 BF4– | Composite electrode | 1×10-6-0.1mol/L | BNC (Type Q9) | |
972126 ClO4– | Composite electrode | 1×10-5-0.1mol/L | BNC (Type Q9) | |
972140 NH3 – | Composite electrode | 1×10-6-1mol/L | BNC (Type Q9) | |
972150 Residual chlorine electrode | Composite electrode | (0.01-20) ppm (as chlorine gas) | BNC (Type Q9) |