Total organic carbon analyzer / TOC analyzer

    1. TOC Detection Range: 0.1 µg/L-1500.0 µg/L
    2. Conductivity Detection Range: 0.055-6.000 µS/cm
    3. Minimum 1-minute analysis interval (can be set arbitrarily)
    4. Supports external 4-20mA communication
    5. Optional online sampling device, autosampler and automatic calibration kit
    1. Measurement Parameters: TC, TIC, TOC, NPOC
    2. TOC Detection Range: 0.001 mg/L-100.0 mg/L
    3. Sample Injection Volume: 50-6000μL
    4. Carrier Gas: High-purity nitrogen (or CO₂-free air)
    1. Sampling Vial Positions: 24 positions
    2. Sampling Vial Volume: 40 mL
    3. Unique sampling needle design with high durability
    4. Real-time display of the sampling process for visualized operation
    1. TOC Detection Range: 0.1 µg/L-1500.0 µg/L
    2. Conductivity Detection Range: 0.055-6.000 µS/cm
    3. Minimum 1-minute analysis interval (can be set arbitrarily)
    4. Optional autosampler and automatic calibration kit
    1. Online TOC Analyzer
    2. TOC Detection Range: 0.1 µg/L-1500.0 µg/L
    3. Conductivity Detection Range: 0.055-6.000 µS/cm
    4. Supports external 4-20mA communication
    5. Optional automatic calibration kit for one-key automatic calibration
    1. Measurement Parameters: TC, TIC, TOC, NPOC
    2. TOC Detection Range: 0.050-35000mg/L
    3. Sample Injection Volume: 20-1000μL
    4. Carrier Gas: High-purity oxygen (99.999%)
    1. Sampling Vial Positions: 30 positions
    2. Sampling Vial Volume: 60 mL
    3. Unique sampling needle design with high durability
    4. Real-time display of the sampling process for visualized operation
    1. Measurement Parameters: TC, TIC, TOC, NPOC
    2. TOC Detection Range: 0.050-35000mg/L
    3. Sample Injection Volume: 20-1000μL
    4. Carrier Gas: High-purity oxygen (99.999%)
    1. Sampling Vial Positions: 81 positions
    2. Sampling Vial Volume: 40 mL
    3. With precise positioning and highly automated design
    1. Maximum sample size: 100 mg
    2. Electronically cooled sample boat
    3. Multiple sample introduction speeds are available
    1. Detector: NDIR
    2. Parameters: TC, TIC, TOC, NPOC
    3. Measurement Range: 0-1000mg/L
    4. Detection Limit: TC: 50μg/L  IC: 20μg/L
    5. Repeatability: ≤3%
    6. Digestion Mode: High Temperature Combustion
    1. Detector: NDIR
    2. Parameters: TC, TIC, TOC, NPOC
    3. Measurement Range: 0-10000mg/l (ppm)
    4. Detection Limit: 5 μg/l (ppb)
    5. Gas Requirement: Nitrogen ≥99.995%
    6. Automatic leaking check system
    7. Flow rate controlling system
    8. Method: Wet Chemical Oxidation by UV
    1. Conductivity (Off-line)
    2. Test items: TOC
    3. Detection Range: 0.001-1.5mg/l(ppm)
    4. Detection limit: 1 ppb
    5. Analysis time: 3 min
    6. Sample flow speed: 1 ml/min
    7. Continuous sample feed
    8. For microelectronics water,purified water, water for injection
    1. Conductivity (On-line)
    2. Parameters: TOC
    3. Detection Range: 0.001-1.5mg/l(ppm)
    4. Detection limit: 1 ppb
    5. Analysis time: 3 min
    6. Sample flow speed: 1 ml/min
    7. Continuous sample feed
    8. For microelectronics water,purified water, water for injection

    Get Quotes Now!