- DM-3005A, Up to 35% off (June – August)
- Advanced U-tube vibration, more accurate results
- Excellent display and operation logic, helping efficient operation
- Support automatic injection, achieve higher throughput
- Ensure compliance, use with confidence
Density Meter, DM Series
Description
DESCRIPTION
DESCRIPTION
- Color LCD touchscreen.
- Android operating system.
- HD camera video for detection.
- Minimum sample volume is approx. 2mL to 3mL for measuring each time.
- Designed with the built-in Peltier temperature control.
- Fast mode and accurate mode meets different needs.
- Compatible with manual and automatic injection.
- Comply with pharma standards.
- Audit trail is optional for DM-3005, DM-3005A to comply with 21 CFR Part 11.

Advanced U-tube vibration, more accurate results
- The U-tube vibration densitometer only needs 2~3mL of sample at least, which greatly saves your precious experimental samples.
- Peltier temperature control provides you with experimental results at precise temperature.

Excellent display and operation logic, helping efficient operation
- High-definition display of U-tube real-time images, convenient for you to check whether there are bubbles in the U-tube while injecting.
- Follow the built-in SOP to operate, you will get it once you use it.

Support automatic injection, achieve higher throughput
- Standard peristaltic pump to automate your injection, measurement and cleaning processes.
- Ensure accurate results without operator influence.
- Reduce exposure to hazardous materials during the injection process.

Ensure compliance, use with confidence
- Complies with ASTM D4052, D5002, D3505, ISO 12185, IP 559 petroleum standards and all relevant pharmacopoeias.
- Four levels of user management permissions, data reporting, electronic signature.
- Audit trail is optional for DM-3005, DM-3005A to comply with 21 CFR Part 11.
- Built-in network module, equipped with multiple communication interfaces, data can be saved, exported and printed.
INDUSTRY APPLICATIONS
INDUSTRY APPLICATIONS
Beverage Industry | Measuring sugar concentration, food additive indicators , soft drink quality control |
Food Industry | Grape juice, tomato juice, fructose syrup, vegetable oil and canned food processing |
Brewing Industry | Detection of alcohol concentration of liquor, yellow wine, red wine, beer, fruit wine, rice wine, etc. |
Chemical Industry | Chemical urea, detergent, glycol, acid, alkali and polymer density testing |
Pharmaceutical Industry | Quality control of raw materials and finished products, determination of specific gravity and density (relative density)
of pharmaceutical preparations |
Petrochemical Industry | Crude oil API index, gasoline, diesel, kerosene density detection, additive mixing ratio process monitoring |
Machining | Cleaning agent testing for metal processing, machine manufacturing, automotive industry, and electronic appliances |
Flavors and Fragrances | Edible flavors, daily flavors, tobacco flavors, food additives and spices |
Testing Agency | Standard laboratories, statutory testing agencies, third-party testing of liquid density measurement |
SPECIFICATIONS
SPECIFICATIONS
Model | DM-3005 | DM-3005A | DM-3004 |
Measuring Range | |||
Density | 0.00000 g/cm³ to 3.00000 g/cm³ | 0.0000 g/cm³ to 3.0000 g/cm³ | 0.0000 g/cm³ to 3.0000 g/cm³ |
Temperature | 5 ℃ to 70 ℃ | 5 ℃ to 70 ℃ | 5 ℃ to 50 ℃ |
Accuracy | |||
Density | ±0.0001 g/cm³ | ±0.0003 g/cm³ | ±0.0005 g/cm³ |
Temperature | ±0.05 ℃ | ±0.05 ℃ | ±0.1 ℃ |
Repeatability | |||
Density | ±0.00005 g/cm³ | ±0.0001 g/cm³ | ±0.0002 g/cm³ |
Precision | |||
Temperature | ±0.02 ℃ | ±0.02 ℃ | ±0.05 ℃ |
Digital Resolution | |||
Density | 0.00001 g/cm³ | 0.0001 g/cm³ | 0.0001 g/cm³ |
Temperature | 0.01 °C | 0.01 °C | 0.01 °C |
Feature | |||
Measuring mode | Density (g/cm³)
Density (kg/cm³) 4 ℃ / 20 ℃ / 25 ℃ / Synthermal specific gravity of water More than 30 built-in units such as Density, Specific gravity, Alcohol, API, Brix, Urea, User-defined, etc. |
Density (g/cm³)
Density (kg/cm³) 4 ℃ / 20 ℃ / 25 ℃ / Synthermal specific gravity of water User-defined |
Density (g/cm³)
Density (kg/cm³) 4 ℃ / 20 ℃ / 25 ℃ / Synthermal specific gravity of water |
Injection | Manual / Automatic (peristaltic pump) | ||
Injection check | 1080P HD camera, video check, photo check | ||
Calibration | Dry air & Distilled water, Multi-point calibration | ||
Drying pump | Built-in DC air pump, connected to the drying bucket, can provide continuous dry air | ||
Atmospheric pressure compensation | Built-in atmospheric pressure sensor, automatically compensates for atmospheric pressure | ||
User management permissions | Four levels | Four levels | / |
Electronic signature | Yes | Yes | / |
Audit trail | Optional FDA software | Optional FDA software | / |
Report format | PDF / Excel | ||
Technical Data | |||
U-tube | Quartz glass | ||
Minimum sample volume | Approx. 2mL to 3 mL | ||
Temperature control | Peltier (high precision platinum resistance, digital PID regulation, PWM temperature control) | ||
Display | 10.1″ color LCD touchscreen | ||
Operating system | Android | ||
Internal storage | 128G | ||
User management | 200 | 200 | / |
Method management | 200 | 200 | 100 |
Test result record | 200,000 | 200,000 | 100,000 |
Communication interfaces | RS232, USB, RJ45 | RS232, USB, RJ45 | RS232, USB |
Connect PC, LIMS | Yes | Yes | Yes |
Printer (Optional) | Thermal printer
Stylus printer Wifi printer |
Thermal printer
Stylus printer Wifi printer |
Thermal printer
Stylus printer |
Power supply | AC 100 to 240 V, 50/60 Hz, 120W | ||
Product dimensions (L×W×H) | 439 mm × 350 mm × 217 mm | ||
Package dimensions (L×W×H) | 720 mm × 470 mm × 390 mm | ||
Net weight | 12 kg | 12 kg | 8.5 kg |
Gross weight | 20 kg | 20 kg | 15 kg |
RElATED VIDEO
RElATED VIDEO
Working under the principle of U-tube vibration, it can measure liquid density quickly, and has the functions of electronic excitation, vibration frequency counting and display. By injecting a small amount of samples into the vibrating sample tube, the density of the sample can be calculated according to the change of the vibration frequency of the sample tube and the calibration data.
Get Social