Chat with us, powered by LiveChat

Multi-parameter Water quality Meter, BEP-M Series

  1. Automatic temperature compensation
  2. Auto-Read function senses
  3. Calibration due to alarm
  4. Reset function
  5. 500 data sets
  6. USB communication interface

Share the product

Description

Feature:

pH
Multiparameter water quality meter is equipped with a 6.5 inches backlit LCD display
1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers
Automatic electrode diagnosis shows the pH slope and offset
ORP
1 point offset calibration allows adjusting the displayed value to a known standard
Relative and absolute millivolt modes ensure the reliable ORP measurements
Ion Concentration
2 to 5 points calibration, including the 8 concentration points can be selected
Direction concentration readout simplifies the measurement process
Automatic electrode diagnosis shows the calibration points and slopes
Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency
Conductivity/TDS/Salinity/Resistivity
1 to 5 points calibration with automatic recognition for conductivity standards
Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater, and practical salinity measurement modes
Automatic electrode diagnosis shows the calibration points and factors
Dissolved Oxygen
1 or 2 points calibration using the air-saturated water or zero oxygen solution
Salinity and barometric pressure compensations eliminate the measurement error

pH meter pH meter

General Features
Automatic temperature compensation ensures accurate readings over the entire range
Auto-Read function senses and locks the measurement endpoint
Calibration due alarm prompts the user to calibrate the meter regularly
Setup menu allows setting the number of calibration points, resolution, stability criteria,
temperature unit, date and time, etc.
Reset function automatically resumes all settings back to the factory defaults
Expanded memory stores or recalls up to 500 data sets
USB communication interface for data transfer and timed interval readings
Ordering Information
BEP-M900: pH/conductivity/dissolved oxygen electrodes, temperature probe, pH buffer sachets, conductivity standard solutions, DO electrolyte solution, membrane cap, electrode holder, USB cable, and power adapter
BEP-M901/902: pH/conductivity electrodes, temperature probe, pH buffer sachets,
conductivity standard solutions, electrode holder, USB cable, and power adapter
BEP-M903: pH/dissolved oxygen electrodes, temperature probe, pH buffer sachets, DO
electrolyte solution, membrane cap, electrode holder, USB cable, and power adapter
BEP-M904: Conductivity/dissolved oxygen electrodes, temperature probe, conductivity
standard solutions, DO electrolyte solution, membrane cap, electrode holder, USB cable
and power adapter

Measurement Parameters
BEP-M900: pH, mV, relative mV, ion concentration, conductivity, TDS, salinity, resistivity, DO, temperature
BEP-M901: pH, mV, conductivity, TDS, temperature
BEP-M902: pH, mV, relative mV, conductivity, TDS, salinity, resistivity, temperature
BEP-M903: pH, mV, relative mV, DO, temperature
BEP-M904: Conductivity, TDS, salinity, resistivity, DO, temperature

Multi-parameter Water quality Meter BEP M Series detail 11

Specifications

Model BEP-M900 BEP-M901 BEP-M902 BEP-M903 BEP-M904
pH Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point
Ion Range 0.001~19999 (depending on the range of ISE)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1
Accuracy ±0.5% F.S.
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°c
Cell Constant K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1
Accuracy ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01
Accuracy ±1% F.S.
Resistivity Range 0.00~20.00MΩ
Resolution 0.01
Accuracy ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0%
Calibration Points 1or 2 points
Barometric Pressure Correction 60.0~112.5kPa/450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Dimensions and Weight 210(L)×188(W)x60(H)mm,1.5kg

    Contact Us Now!

    We will usually contact you within 24 hours. You could also call us (+86-531-88982330) during working hours ( 8:30 am to 5:45 pm UTC+8 Mon.~Sat. ) or use the website live chat to get prompt reply.

    Contact Info

    Rm. 2014, Bldg. 3, Ligaoguojihuayuan, No. 1222, West Aoti Road, Lixia District, Jinan, Shandong

    Phone: +86-531-88982330

    Fax: +86-531-88983691

    Web: www.infitek.com

    Go to Top