Chat with us, powered by LiveChat

Patient Monitor, PM-12

  • Available for neonatal monitoring
  • 12.1″ color TFT screen
  • With drug dose calculation and titration table
  • Respiration monitoring with apnea alarms
  • Supporting wire or wireless network
  • Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temp

Share the product

Description

1. 12.1″ color TFT screen
2. Multi‐channel display
3. Big font interface
4. ST and arrhythmia analysis
5. Drug dose calculation and titration table
6. OxyCRG dynamic view display
7. Respiration monitoring with apnea alarms
8. Alarm review, arrhythmia review
9. Patient info. Input
10. Anti‐defibrillation design
11. NIBP over pressure protection
12. Plug‐in rechargeable battery, AC/DC available.
13. Supporting wire or wireless network.

Specifications

ECG Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:    I, II, III, avR, avL, avF, V
Wavef orm: 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection:    I, II, III,
Wave form: 1 ch
Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
HR and Alarm Range:Adult    15 ~ 300 bpm
Neo/Ped    15 ~ 350 bpm
Accuracy:  ±1% or±1bpm, which is greater
Resolution:1 bpm
Sensitivity:> 200 (uVp-p)
Differential Input Impedance:> 5 MΩ
CMRR Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential:  ±300mV
Leakage Current:   < 10 uA
Baseline Recovery: < 3 S After Defi.
ECG Signal Range:  ±8 m V ( Vp-p )
Bandwidth:  Surgery    1 ~ 20 Hz
Monitor     0.5 ~ 40 Hz
Diagnostic  0.05 ~ 130 Hz
Calibration Signal: 1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range:  Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting:      Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
PNP, PNC,Alarm Available,Review Available
Respiration Method :Impedance between R-F(RA-LL)
Differential Input Impedance:> 2.5 MΩ
Measuring Impedance Range:   0.3~3 Ω
Base line Impedance Range:    200~4 KΩ
Bandwidth: 0.1~2.5Hz
Resp. Rate:Measuring and Alarm Range
Adult 0 ~ 120 Brpm
Neo/Ped 0 ~ 150 Brpm
Resolution 1 Brpm
Accuracy ±2 Brpm
Apnea Alarm:10 ~ 40 S
NIBP Method:   Oscillometric
Mode:     Manual, Auto, STAT
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range :   40 ~ 240 bpm
Alarm Type :SYS, DIA, MEAN
Measuring and alarm range: Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution:     1mmHg
Accuracy:Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection:   Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
SpO2 Measuring Range: 0 ~ 100 %
Alarm Range:     0 ~ 100 %
Resolution:      1 %
Accuracy:70% ~ 100%  2 %
0%  ~  69% unspecified
Actualization interval about      1 Sec.
Alarm Delay:     10 Sec.
Pulse Rate:      Measuring and Alarm Range 20~300 bpm
Resolution:1bpm
Accuracy ±3bpm
TEMP Channel: 2
Measuring and Alarm Range 0 ~ 50 ℃
Resolution:     0.1 ℃
Accuracy : ±0.2 ℃
Actualization intervalabout     1 Sec.
Average Time Constant:    < 10 Sec.
IBP Label:  ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range:ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP-10 ~ 40 mmHg
P1 / P2-10 ~ 300 mmHg
Press Sensor:   Sensitivity 5  uV/V/mmHg
Impedance 300-3000Ω
Resolution:     1 mmHg
Accuracy:±2% or 1mmHg which is greater
Actualization interval : about 1 secretary
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station

    Contact Us Now!

    We will usually contact you within 24 hours. You could also call us (+86-531-88982330) during working hours ( 8:30 am to 5:45 pm UTC+8 Mon.~Sat. ) or use the website live chat to get prompt reply.

    Contact Info

    Rm. 2014, Bldg. 3, Ligaoguojihuayuan, No. 1222, West Aoti Road, Lixia District, Jinan, Shandong

    Phone: +86-531-88982330

    Fax: +86-531-88983691

    Web: www.infitek.com