- Number of Cups: 12
- Capacity of Single Cup: 2000 ml
- Basket capacity: 150 pcs
- Frequency of Agitation: Adjustable 0-6 times/minute
- Temperature Range: RT – 80℃ ±1℃
Automated Tissue Processor, TSP-3C
Description
- Imported high-quality parts, smooth operation, low noise, ergonomic design
- Equipped with 7-inch intelligent color touch LCD display, real-time display of working status, clear display
- Fully intelligent design, enabling timely determination and automatic recovery from an abnormal event
- Real-time visual simulation with iconsdisplays working status dynamically, clearly and intuitively
- Green inner-cycling air purification system to efficiently adsorb and remove poisonous gas; well-sealed gas-effluxion mechanism to effectively improve the operational environment, environmentally-friendly and safe
- This system can be automatically started at any timeas programmed
- Processing duration is automatically calculated and displayed on the screen, allowing user to make a more efficientwork plan
- Automatic fan control: fully open when moving to upper tank, opens once every minute when moving to lower tank, each time for 10 seconds
- Automated light control: stays ‘on’all the time during programming; stays ‘off’during the automatic operation and can be automatically turned ‘on’ anytime by touching the screen or any key and stays ‘on’ for 2 minutes
- Internal dry heating mechanism with high-precision temperature control: Automatically determines the time of heatingfor energy efficiency
- Low-energy-consuming control circuit with power protection function
- Drainage mimics manual shaking, thorough drainage, reduces reagent mixing, extends reagent usage cycle
- Full automatic stirring throughout the process, enables more thorough and complete tissue immersion, optimal dehydration effect
Technical Specifications
| Number of Cups | 12 (The 1st to 9th stations for reagents and the 10th to 12th stations for paraffin melting) |
| Capacity of Each Cup | 2000 ml |
| Dehydration basket capacity | 162*62*129 (mm) (125 dehydration cassettes) |
| Single tank processing time | |
| First tank | Adjustable from 0~99 hours 59 minutes |
| Other tanks | Adjustable from 0~23 hours 59 minutes |
| Wax tank temperature control range | RT – 80℃ |
| Programmable settings | 20 sets. |
| Temperature Control Precision | ±1℃ |
| Drainage time | Adjustable from 10~60 seconds, increment of 10 seconds.shake/drip above cup |
| Frequency of Agitation | Adjustable within 0 – 6 times/minute |
| Tissue protection tanks | Adjustable from 1~7 tanks |
| Working Voltage | AC220V±10% 50Hz (standard model)AC110V±10% 60Hz |
| Power | 500 W |
| Dimensions | 1170×465×535mm (W×D×H) |
| Net weight | 85kg |
| Category | Title | File type/size | Download |
| Brochure | Brochure – Tissue Processor | PDF(377 KB) | download |

Get Social