Chat with us, powered by LiveChat
    1. Range of rotation: 1000-32000 r/min
    2. Processing capacity: 0.2-150ml (H2O)
    3. Processing viscosity: 5000mpas
    • Observer Angle:2°/10°
    • Wavelength Interval:10nm
    • Wavelength Range:400-700nm
    • Measuring Aperture: φ11mm
    1. Capacity(L/cu.ft): 105/3.70, 485/17.12
    2. Temperature range(℃): -60℃~-25℃
    3. Advanced Cooling System: High-performance compressor, reasonable refrigeration layout, more stable refrigerant
    4. Stable and highly precise temperature control: Accuracy up to 0.1℃; Can run smoothly at the lowest temperature for a long time
    5. Convenient after-sales service: 2 years warranty
    • Test items:pH , pCO2,pO2, K+ , Na+, Cl- , Ca++, Hct
    • Sample:whole blood, serum, plasma, dialysate, CSF
    • Analysis time:<90s
    • Sample volume: 95μL Whole blood;50μL Capillary blood
    • Test items:pH,pCO2, pO2 ,Hct
    • Sample:whole blood, serum, plasma, dialysate, CSF
    • Analysis time:<90s
    • Sample volume: 95μL Whole blood;50μL Capillary blood
    1. Measuring technology: Ion Selective Electrode(ISE)
    2. Item:K、Na、Cl、 iCa、nCa、TCa、pH 、TCO2 、AG
    3. Analysis speed: ≤25 seconds
    4. Sample consumption:60-300μL(Item 3 to item 11)
    5. Storage:Up to 10000 test results
    6. 7 inches color super large high-definition touch screen
    7. Optional Auto sampler :  39 positions (Including 5 emergency and 2 QC)
    • Measuring technology: Ion Selective Electrode(ISE)
    • Item:K, Na, Cl, iCa, nCa, TCa, pH
    • Analysis speed: ≤40seconds
    • Sample consumption:150μL
    • Storage:Up to 10000 test results
    1. Measuring technology: Ion Selective Electrode(ISE)
    2. Item:K、Na、Cl、 iCa、nCa、TCa、pH 、TCO2 、AG
    3. Analysis speed: ≤25 seconds
    4. Sample consumption:60-300μL(Item 3 to item 11)
    5. Storage:Up to 10000 test results
    6. Optional Auto sampler :  39 positions (Including 5 emergency and 2 QC)
    1. Timing setting range:1-999 (min/s)
    2. Temperature control accuracy:±0.2
    • 12positions, each position is numbered
    • Accommodates sample in tubes(diameter 10~29mm), volume(1~ 50ml)
    • With liquid-level sensor, have alarming function when dry heating
    • The lifting needle valve controls the gas consumption at each position
    • Independent blowpipes, without cross contamination
    • Gas needle channel can be used in combination or individually
    • High precision and wide range of temp. control.
    • Lifting seat can be adjusted steplessly with one hand
    1. Temperature range: Room temperature +5℃~ 300℃
    2. Measuring range: 0.1 ~ 100%
    3. Temperature accuracy: ±1℃
    4. Reproducibility: Relative error 1%
    5. Sample weight: 0.5 ~ 15g
    1. Measuring range: 0.1%-100%
    2. Temperature control range: RT+5℃-300℃
    3. Temperature control accuracy: ±1℃
    4. Sample quantity: 6 /per time
    5. Solvent cup volume: 150ml
    1. Temperature range: Room temperature+5℃~ 280℃
    2. Measuring range: 0 ~ 100%
    3. Temperature accuracy: ±1℃
    4. Sample weight: 0.5 ~ 15g(generally 2 ~ 5g,depending on sample)
    • 2-6 heating system
    • Self-contained solvent recovery function
    • Built-in circulating water pipeline
    • Adopt imported ARM processor
    • 7-inch full-color 24bit touch screen
    • Double-row winding of customized nickel-chromium wire

    Get Quotes Now!

    We will usually contact you within 24 hours. You could also call us (+86-531-88982330) during working hours ( 8:30 am to 5:45 pm UTC+8 Mon.~Sat. ) or use the website live chat to get prompt reply.

    Contact Info

    Rm. 2014, Bldg. 3, Ligaoguojihuayuan, No. 1222, West Aoti Road, Lixia District, Jinan, Shandong

    Phone: +86-531-88982330

    Fax: +86-531-88983691

    Web: www.infitek.com

    Go to Top